Skip to content
Water Tank Tech

A new skin inside the tank you already have.

Protective internal linings for steel and reinforced concrete tanks. Warranty of 2 to 10 years by mutual agreement; insulation between liners available.

HDPE lining system

An impermeable geomembrane barrier. Chlorine added to kill bacteria attacks concrete and steel; the liner keeps the water off both.

HDPE sheet
Thickness range0.3 – 3.0 mm
Strength at break71 / 85 N/mm
Strength at yield38 / 45 N/mm
Elongation at break700%
Dimensional stability± 2%

Strength values are per direction. The full per-thickness property table is available on request.

Application
Steel tanks, R.C. tanks, sewage tanks, aquaculture and landscape ponds, irrigation channels
Expected life span
More than 20 years
Installation
Qualified installers only
  • Inert geomembrane, approx. 97.5% virgin polyethylene and 2.5% carbon black; no fillers or extenders. Non-toxic.
  • UV stabilised and resistant to rodents, microorganisms, oily wastes, acids and hydrocarbons.
  • Flexible and easy to weld to tank shapes; high puncture and crack resistance, rust free.
  • Chlorine neutralises concrete surfaces and corrodes reinforcement; an impermeable liner stops that cycle of repairs.

Stainless steel lining, SS 304 / 316L

Hygienic, food-grade steel lining for reinforced concrete tanks, with no chemical reaction with the concrete walls.

Application
Internal lining for reinforced concrete (R.C.) tanks
Expected life span
More than 50 years
Installation
Water Tank Tech qualified installers only
  • Hygienic, food-grade steel for lifetime protection against corrosion with minimum maintenance.
  • A protective layer against corrosion caused by the oxidation of chlorine in the water of R.C. tanks.
  • SS 304: 0.08% carbon and 8% nickel, resistant to moderately aggressive organic and reducing acids.
  • SS 316L: molybdenum for higher corrosion resistance; low carbon avoids carbide precipitation during welding.
  • Excellent fabricability; no chemical reaction with concrete walls. Insulation between liners available.

Installation, in order.

How a liner goes in, from surface inspection to the signed completion certificate.

  1. Preliminaries

    Inspect the area. The surface must be firm and unyielding, with no sharp changes in grade that could damage the liner.

  2. Fixing

    Liners attach to steel or concrete walls with bolted stainless steel or HDPE batten strips.

  3. Wedge welding

    Overlaps are heated and pressed while molten into a double-track weld with an air channel for pressure testing.

  4. Extrusion welding

    For pipe penetrations, patches and non-linear seams, using molten polyethylene of the same resin.

  5. Seam testing

    Every field seam is tested over its full length by spark or vacuum as seaming progresses.

  6. Drawings and support

    Detailed drawings, technical and estimating support for the most economical configuration.

  7. Completion

    A final joint inspection, then a signed completion certificate and the agreed warranty.

123
Wedge weld, in section. Two weld tracks (1, 2) fuse the overlapped sheets; the air channel between them (3) is pressurised to test the seam without cutting it.

Send the tank size and its condition.